I have two fridge/freezers and a chest freezer. None of them are “smart” and all use mechanical controls. A few months ago I put all three on zigbee plugs, and created an automation to monitor and notify via ntfy if it detects any problems:

  • Notify if compressor doesn’t switch between on/off state for two hours (Based on power usage, detects stuck thermostat, door left open, defrost cycle issue, failed compressor, plug fallen out the socket or anything else which causes the fridge to not run normally). This uses a helper binary sensor which shows “on” if power usage > 40W and fires the notification if the state of the binary sensor doesn’t change for more than 2h.

  • Notify if any of the plugs are turned off or go offline for more than 15 minutes. (This is what fired overnight)


Just after midnight, I was woken by a notification saying two of them had gone offline at the same time. Got out of bed to check and found the RCD breaker feeding two of them had tripped. Isolated the fault to the kitchen fridge, it trips the breaker the moment it is turned on. Left the kitchen fridge unplugged and transferred the contents to the other two plus a spare in the garage. Without this automation it’s likely I wouldn’t have found this problem until the following evening after work when it would have been too late.

Interested to hear if anyone else does similar monitoring using their HA?

  • ClemmysGuttata@piefed.social
    link
    fedilink
    English
    arrow-up
    2
    ·
    24 hours ago

    I had something similar happen with my aquarium. A water heater thermostat failed and the heater got stuck in the powered-on state. I don’t know how long it might have taken me to notice that it was heating the aquarium water several degrees higher than the temperature it was set to if not for the power draw alert I had set up on the outlet to catch that type of failure.

    • r0ertel@lemmy.world
      link
      fedilink
      English
      arrow-up
      2
      ·
      1 hour ago

      Why on earth do these aquarium heaters fail in the on position?! This seems like such a bad design decision.

      After going on vacation and boiling my fish for a week, a friend suggested to get two heaters, each sized to heat 60% of the tank. The chances of both failing simultaneously is slim.

  • Mikelius@lemmy.ml
    link
    fedilink
    English
    arrow-up
    23
    ·
    3 days ago

    My save was a leak sensor. I put one below the water softener which triggers an alarm off it detects water and will shut the valve to the house too. The day before a 3 month trip, the alarm went off and we saw we had a huge leak in the back of the softener. Had to shut off the water to the house before we left, but man that could have been horrible to come home to.

  • tiptoes@sh.itjust.works
    link
    fedilink
    English
    arrow-up
    33
    ·
    3 days ago

    I use two temperature sensors. One directly under the freezer, another on a cabinet beside the freezer at the same height.

    Normally their temperatures are very close, the freezer one less than 1C lower than the control. If the door doesn’t seal fully (door closed but seal is not fully closed due to obstruction or other reason), the difference quickly increases and HA sends a “Door Open” alert.

    It’s sensitive enough to detect even small misalignments, and more reliable than the door close alarm built in the fridge.

  • shalafi@lemmy.world
    link
    fedilink
    English
    arrow-up
    4
    ·
    2 days ago

    Neat! However your food would have been just fine with no one opening the door over that time. This is common knowledge down on the Hurricane Coast. :)

    After Hurricane Isaias we didn’t have power for a day until I got the genny from camp back home and wired up our house and 4 neighbors. Everyone’s food was just fine.

    Anyway, how does an electric plug catch anything but a complete power failure? Sounds like you have something intricate figured out.

    • blargh513@sh.itjust.works
      link
      fedilink
      English
      arrow-up
      4
      ·
      2 days ago

      Many plugs do power monitoring.

      You get a baseline run rate so you know what normal operation looks like. Then you set automation when there are any deviations from normal, you are notified.

      You can do so much correlation with HA, it is fantastic for this sort of thing.

  • czardestructo@lemmy.world
    link
    fedilink
    English
    arrow-up
    19
    ·
    3 days ago

    My wife notoriously keeps leaving the basement freezer door adjar. So I drilled a hole in the top of the freezer, stuffed in a temp sensor, sealed it up and connected it to a pi. Pushes data via Mqtt to HASS so now it harasses both of us if the temp gets above a certain threshold.

      • czardestructo@lemmy.world
        link
        fedilink
        English
        arrow-up
        7
        ·
        3 days ago

        Sorry I meant only the temp sensor passes through into the freezer, the wire continues up and out to the pi outside the freezer and I sealed the hole and wire with RTV.

      • czardestructo@lemmy.world
        link
        fedilink
        English
        arrow-up
        3
        ·
        2 days ago

        I had the sensor already. Also gives me data of when someone opens the door because you see immediate temp rises. Also notifies me if the compressor fails.

          • czardestructo@lemmy.world
            link
            fedilink
            English
            arrow-up
            4
            ·
            2 days ago

            Dude its a sickness. I’m an organized pack rat, I have all manner of crap to cobble together whatever. My property has a pi powered; wood stove monitor, doorbell, cuckoo clock, a friggin trailer,the list continues. I’m having fun but yea, hacky setups all over the place.

    • njordomir@lemmy.world
      link
      fedilink
      English
      arrow-up
      1
      ·
      24 hours ago

      Protip, make sure the water sensor is not just on the floor, but on the lowest part of the floor. If a pipe breaks and there is a 0.25% grade away away from the sensor, you could still miss the notification entirely.

  • SayCyberOnceMore@feddit.uk
    link
    fedilink
    English
    arrow-up
    6
    ·
    3 days ago

    Not thought of using power monitoring for the fridge / freezer (I’m using temperature instead)

    I do have a simple dehumidifier which seized it’s fan and was drawing several amps. So I replaced the fan and put a 2A safety limit on it’s power monitoring socket.